Chapter 2 89
Test Descriptions
TEST_40 - CPD Softer Handoff
6. The Sector B pilot strength is decreased until the mobile station
detects signal strength below T_DROP for a time period greater than
T_TDROP. Once again, the Sector A and Sector B signal strength
settings are displayed, along with the mobile-reported pilot signal
strength and the handoff Sector B Ec/Io compared to T_DROP.
7. The following information is printed to the TESTS (IBASIC
Controller) screen.
For a neighbor Ec/Io=-14.5 & active Ec/Io=-10.5
The reported neighbor pilot strength= 28
Sector B Ec/Io for T_ADD -14.5dB
For a candidate Ec/Io=-10.5 & active Ec/Io=-12.5
The reported candidate pilot strength= 23
The reported active pilot strength= 27
Softer Handoff successful: <YES/NO>
For a candidate Ec/Io=-16.5 & active Ec/Io=-10.5
The reported candidate pilot strength= 34
Sector B Ec/Io for T_DROP -16.5dB
Most Test Set functions used during this test are found on the CDMA
Mobile Reporting screen.
Pass/Fail Limits Used
•None
Parameters Used
9. CPD BID Number
11. CPD NID Number
12. CPD SID Number
18. RT Prot Std [0=95 1=95A 2=TSB74 3=ARIB]
19. RT Rate Set Selection [0=9600 1=14400]
22. RX RF Level for Signaling (dBm)