Chapter 2 49
Test Descriptions
TEST_21 - CPA Origination
TEST_21 - CPA Origination
Description
This test simulates a call from the cellular phone to the base station
(cell site) by putting the phone in service and having the operator
originate a call from the handset. Specifically, this test performs the
following:
1. The test system simulates a control channel.
2. The operator is instructed to dial 123 123 4567 after the MSUT has
service. (Service is indicated by the NO SERVICE light going off or
the SERVICE light illuminating on the MSUT.)
3. Performs 3 of 5 majority voting on the Reverse Control Message
4. Performs BCH error detection and correction of the Reverse Control
Message, Wideband data
5. Tests each section of the origination message, bit by bit
6. Sends an Initial-Voice-Channel-Designation order to the MSUT
directing it to tune to a voice channel obtained from the Channel
Information table.
7. Makes a power measurement on the initial voice channel to verify
that the voice channel was obtained. The power level measurement
result is not displayed in this test.
It is not necessary to register the phone with the test set by running
TEST_01 - CPA Registration before running this test. TEST_21 - CPA
Origination will read the MSUT’s Mobile Identification Number (MIN)
and the test set will retain it for use in performing other tests.
If the channel number from the table has an L, M, or U suffix, the
phone will be directed to a narrow voice channel. If the channel number
has no suffix, the phone will be directed to a wide voice channel.
Pass/Fail Limits Used
• None
Kommentare zu diesen Handbüchern