Chapter 2 85
Test Descriptions
TEST_38 - RXD Traffic Channel FER
Refer to the Agilent 8924C Reference Guide for information about the
FER measurement field and the Max Frames and Confidence setting
fields.
Pass/Fail Limits Used
The Pass/Fail limits for this test are hard-coded into the software. The
values used were obtained from TIA/EIA IS-98 minimum standard for
the Demodulation of Forward Traffic Channel in Additive White
Gaussian Noise test.
Parameters Used
• 9. CPD BID Number
• 11. CPD NID Number
• 12. CPD SID Number
• 18. RT Prot Std [0=95 1=95A 2=TSB74 3=ARIB]
• 19. RT Rate Set Selection [0=9600 1=14400]
• 22. RX RF Level for Signaling (dBm)
• 33. RXD Maximum Frames for FER