100 Chapter 2
S:\agilent\83217\OPT001\BOOK\CHAPTERS\tdscrip.fm
Test Descriptions
TEST_47 - RXD Sensitivity Level Search
TEST_47 - RXD Sensitivity Level Search
Description
This test brackets the actual receiver sensitivity by measuring the
frame error rate (FER) as the mobile station received power is reduced
from that specified by parameter parameter 34. RXD RF Level for
Sensitivity (dBm) to a level that generates an FER greater than that
specified by parameter 35. RXD Sensitivity FER Search Specification
(%). The actual search sensitivity will be at some point between the last
two measured mobile station received power levels.
1. A Service Option 2 (or 9 if parameter 19. RT Rate Set Selection
[0=9600 1=14400] is set to 1) call is attempted, unless a Service
Option 2 or 9 call is already connected. If the MSUT has not
registered, the call attempt may be unsuccessful and the error
message “Failed to establish a call in test <>” will be displayed. To
correct this problem, perform the CPD Registration test.
2. The parameter “RXD RF Level for Sensitivity” is retrieved and that
value is entered in the Sector A Power field.
3. The parameter “RXD Maximum Frames for FER” is retrieved and
that value is entered in the Sector A Max Frames field.
4. The FER test is turned on with a confidence level of 95 percent.
5. The FER Spec field is set to the value specified in parameter 35.
RXD Sensitivity FER Search Specification (%).
6. Traffic Channel level and data rates are set up and the first FER
measurement is triggered. The test software waits for the GPIB
interrupt to determine when the test is complete. The test times out
and continues if the interrupt does not occur within a period
bounded by the value specified in parameter 33. RXD Maximum
Frames for FER. If a timeout occurs, a timeout message displays and
the test continues.
7. Sector A Power is reduced in 0.5-dB steps until the measured FER is
greater than that specified in parameter 35. RXD Sensitivity FER
Search Specification (%) . The test then stops.
8. The following information is printed to the TESTS (IBASIC
Controller) screen for all FER measurements after the first one
greater than 0.0 percent:
RXD Senstvty FER@ <current mobile received power in dBm>
<FER in %>