Test Descriptions
TEST_18 - RXA SINAD
TEST_18 - RXA SINAD
Description
This test sets and measures the ratio, expressed in dB, of:
• Signal + Noise + Distortion,
• to Noise + Distortion.
The receiver’s SINAD is measured at the RF level specified by
parameter 29. RXA RF Level for SINAD (dBm).
NOTE
Audio connections from the radio to the test system are required for this
test.
Receiver SINAD is measured at the receiver’s audio output. This
measurement differs from a distortion measurement in that it is
conducted at low RF input levels where the noise contribution is
significant.
This test is intended to measure receiver sensitivity. Receivers are
typically required to provide at least 12 dB SINAD (less than 25% noise
and distortion) for RF input levels below 1 microvolt.
• The RF signal (level set by the parameter 29. RXA RF Level for
SINAD (dBm) is modulated to deviate to 8 kHz at a 1 kHz rate with
a SAT tone present.
• The measurement is repeated at high and low supply voltages if
parameter 20. RT Test at Extreme Settings [0=no 1=yes] is set to 1.
• Narrow analog operation uses 3 kHz deviation and DSAT.
Pass/Fail Limits Used
• 10. RXA SINAD (dB)