Carrier 06D Bedienungsanleitung Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
17
PUMP END MAIN BEARING This bearing is a ma-
chined part of the new aluminum oil pump and bearing head
casting. Disassemble bearing head. If bearing is scored or
worn, replace complete bearing head.
CRANKCASE AND MOTOR END MAIN BEAR-
INGS These bearings are not field replaceable. If bearings
are worn or damaged, replace compressor.
Compressor Running Gear Replacement
CRANKSHAFT Install crankshaft through pump end,
carefully guiding it through main bearings. Replace rotor.
Attach equalizer tube assembly to motor end of shaft.
Eccentric shafts must be installed after piston assemblies.
Place motor end counterweight on shaft before inserting shaft
into compressor. See Piston Assembly Replacement.
PISTON ASSEMBLY Attach connecting rods or eccentric
straps to pistons with piston pins and lock in place with piston
pin lock rings. Place lock rings with gap on the side.
They should be tight enough so they cannot be rotated by
finger pressure.
RINGS
1. Check ring gap by inserting each ring separately in
cylinder, approximately
3
/
8
in. from top. Ring gap should
be between .013 and .005 inch.
2. Install compression rings in top piston grooves with side
marked “Top” toward piston head. Install oil ring below
compression ring with notched end on bottom. Stagger
ring gaps around piston.
3. Measure side clearance between ring and piston
(Table 6). Check for free action.
PISTON ASSEMBLY REPLACEMENT
Compressors Using Crankshafts
— Install connecting rod
and piston assemblies into cylinders. Place chamfered sides of
connecting rods against radius of crankpins. Install connecting
rod caps to matching connecting rods through bottom of crank-
case. Be sure chamfered sides of caps are against radius of
crankpins. Caps are locked in place with cap screws. Use 8 to
10 lb-ft to tighten cap screws.
Compressors Using Eccentric Shafts
— Install eccentric
strap and piston assemblies into cylinders. Install eccentric
shaft through pump end, carefully guiding it through
eccentric straps and main bearings. Install pump end counter-
weight to eccentric shaft and replace eccentric strap side
shields.
Turn crankshaft or eccentric shaft to be sure there is no
binding between bearing surfaces and journals. Replace oil
screen, bottom cover plate, valve plates and cylinder heads.
COMPRESSOR MOTOR BURNOUT
Clean-Up Procedure —
If a hermetic motor burns out,
the stator winding decomposes, forming carbon, water and acid
which contaminate refrigerant systems. Remove these contam-
inants from system to prevent repeat motor failures.
1. Close compressor suction and discharge service valves,
and bleed refrigerant from compressor. Save remaining
refrigerant in system.
2. Check control box for welded contactor contacts, welded
overload contacts or burned out heater elements. Check
terminal plate for burned or damaged terminals, insula-
tion, and shorted or grounded terminals. Repair or replace
where necessary.
3. Remove suction and discharge shutoff valve bolts and all
other connections to damaged compressor. Remove
damaged compressor and replace with new compressor.
Replace liquid line filter drier with a drier of one size
larger.
4. Purge new compressor. Triple-evacuate, using the follow-
ing procedure:
a. Evacuate to 5000 microns.
b. Break vacuum with system refrigerant. Pressurize
to 15 psig. Wait 20 minutes to remove moisture.
c. Re-evacuate to 5000 microns.
d. Repeat Step b.
e. Evacuate to 1000 microns or below if possible.
5. Place compressor in operation. After 2 to 4 hours of
operation, check compressor oil for signs of discoloration
and/or acidity. If oil shows signs of contamination,
replace oil charge, filter driers, and clean suction strainer
with solvent. Repeat this procedure until oil stays clean
and acid free for 48 hours of operation.
Do not attempt start-up with terminal cover removed.
Bodily injury or death may result from explosion and/or
fire if power is supplied to compressor with the terminal
cover removed or unsecured. See warning label on termi-
nal cover.