Carrier 06D Bedienungsanleitung Seite 9

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 8
9
Table 2A — 06D Physical Data
*Compressors listed are for R-22 applications. For R-134a and R-507/
404A an 06DR compressor is standard. Factory compressor substitutes
may be made. Contact Carrier Sales Representative.
NOTE: The 06DE8251 compressor unit with the 06DA825 compressor
replaces the 06DE8241 once inventory of the 06DA824 compressor is
depleted.
Table 2B — 07D Physical Data
LEGEND
*Compressor listed is the standard compressor for R-22, air conditioning
duty. An 06DR compressor is standard equipment for low temperature
(R-507/404A) or medium temperature (R-134a) applications. Factory
substitutions may be made. Contact Carrier Sales Representative.
†The condenser listed is for R-22, air conditioning duty and may change
based on the application. Maximum condenser operating pressure:
350 psi refrigerant side, 300 psi water side (“CX” models); 350 psi
refrigerant side, 150 psi water side (“AX” models).
NOTE: The 07DB210 with the 06DA825 compressor replaces the
07DB210 with the 06DA824 once the compressor inventory is depleted.
Table 3 — Factory Switch Settings
LEGEND
NOTES:
1. Values for the high- and low-pressure switches based on R-22.
For other refrigerants, reset to pressure corresponding to satura-
tion temperatures indicated by the listed pressures.
2. Values for oil pressure are above operating suction pressure
(pressure differential between suction and discharge pressures
of oil pump).
CAPACITY CONTROL (Suction Cutoff Type)
Control Set Point (Cylinder Load Point) —
Set
point is adjustable from 0 to 86 psig. Pressure differential
between cylinder load-up point and cylinder unload point is
adjustable from 7 to 19 psi.
To Regulate Control Set Point —
Refer to Fig. 7.
Turn adjustment nut clockwise to its bottom stop (with nut in
this position, set point is 86 psig). Control set point is then
regulated to desired pressure by turning adjustment nut coun-
terclockwise. Every full turn decreases set point by 7.2 psi.
Approximately 12 turns in counterclockwise direction will de-
crease control set point to 0 psig. Table 4 shows steps of control
for the compressor and condensing unit.
Pressure Differential Adjustment —
Turn differ-
ential adjusting screw counterclockwise to its back-stop posi-
tion (differential in this position is 7 psi). Pressure differential is
set by turning adjustment screw clockwise. Every full turn
increases differential by 1.2 psi. Approximately 10 turns in
clockwise direction will increase pressure differential to 19 psi.
UNIT 06D A8081 H3131 A8181 E8251 E3281 E5371
OPERATING WEIGHT (lb)
180 250 265 325 325 330
REFRIGERANT
R-134a, R-22, R-507/404A
COMPRESSOR — 06D*
M808 M313 A818 A825 A328 A537
Cylinders
2446 6 6
Bore (in.)
2222 2 2
Stroke (in.)
1
1
/
4
11
7
/
16
1
1
/
4
1
15
/
32
1
15
/
16
Displacement (cfm at 1750 rpm)
8 13 18.3 23.9 28 37.1
Maximum Rpm
1750
Oil Charge (pt)
34.55.5 8 8 8
High Side Maximum Pressure
450 PSIG
Low Side Maximum Pressure
245 PSIG
CONNECTIONS (in.)
Suction Valve (ODF)
7
/
8
7
/
8
1
1
/
8
1
3
/
8
1
3
/
8
1
3
/
8
Discharge Valve (ODF)
5
/
8
5
/
8
7
/
8
7
/
8
7
/
8
1
1
/
8
UNIT 07D A203 B205 A208 B210 B212 B215
OPERATING WEIGHT (lb)
270 395 420 545 595 620
REFRIGERANT
R-134a, R-22, R-507/404A
COMPRESSOR — 06D*
M808 M313 A818 A825 A328 A537
Cylinders
244666
Bore (in.)
222222
Stroke (in.)
1
1
/
4
11
7
/
16
1
1
/
4
1
15
/
32
1
15
/
16
Displacement (cfm at 1750 rpm)
8 13 18.3 23.9 28 37.1
Maximum Rpm
1750
Oil Charge (pt)
34.55.58 8 8
High Side Maximum Pressure
450 PSIG
Low Side Maximum Pressure
245 PSIG
CONDENSER (Shell and Tube)† Part Number
P701-0605CX P701-0607CX P701-0610CX P701-0615CX P701-0620CX P701-0625AX
Refrigerant Storage
Capacity (lb)
R-134a
17.20 15.90 24.40 31.60 27.40 39.80
2.86 3.16 5.00 7.55 8.47 9.18
R-22
17.00 15.70 24.10 31.20 27.10 39.30
Min Refrigerant Operating
Charge (lb)
2.80 3.10 4.90 7.40 8.30 9.00
R-507/404A
14.70 13.60 20.90 27.10 23.50 34.10
2.80 3.10 4.90 7.40 8.30 9.00
REFRIGERANT CONNECTION (in. ODF)
Inlet
1
5
/
8
1
5
/
8
1
5
/
8
1
5
/
8
1
5
/
8
1
5
/
8
Outlet
1
1
/
8
1
1
/
8
1
1
/
8
1
1
/
8
1
1
/
8
1
1
/
8
WATER CONNECTION (in. FPT)
Inlet/Outlet
111
1
/
4
1
1
/
4
1
1
/
4
2
FPT
Female Pipe Thread
ODF
Outside Diameter, Female
SWITCH TYPE
PRESSURE CHANGE AFFECTING
SWITCH POSITION
Closed Open
High Pressure
210 (±10) (psig) 290 (±10) (psig)
Low Pressure
70 (±4) (psig) 60 (±4) (psig)
Oil Pressure
6 (psid) 11 (psid)
psid
pounds per square inch differential
psig
pounds per square inch gage
802
Seitenansicht 8