Fig. 30 — 42SH Cabinet Dimensions
23
22
21
20
19
†Unit weights are based on dry coils and minimum rows. Weights exclude packaging, valves, and other components.
UNIT
SIZE
NOM
AIRFLOW
(cfm)
DIMENSIONS (in.)
UNIT
WEIGHT†
(lb)
Single Supply Double Supply
CDEFG
ABAB
03 300 14 8 14 6 17 22
3
/
8
2
1
/
2
22
1
/
8
14
3
/
4
202
04 400 14 12 14 8 17 22
3
/
8
2
1
/
2
22
1
/
8
14
3
/
4
247
06 600 14 12 14 8 20 25
3
/
8
2
1
/
2
26
5
/
8
17
3
/
4
262
08 800 14 16 14 10 20 25
3
/
8
2
1
/
2
26
5
/
8
17
3
/
4
286
10 1000 18 16 14 12 24 29
3
/
8
2
1
/
2
31
1
/
8
17
3
/
4
311
12 1200 18 16 14 12 24 29
3
/
8
2
1
/
2
31
1
/
8
17
3
/
4
336
*Drawing provided for reference only. Dimensions may vary with options ordered.
NOTES:
1. Units are fabricated of 18-gage galvanized steel with a 16-gage galvanized fan deck, painted with Arctic White.
2. Risers are piped to coil with valves as specified.
3. Blower, motor, valves, coil, and filter are accessible through the return air opening.
4. Unit and control box are insulated.
5. Riser length = [(floor to floor) +2 in.], maximum riser length = 119 inches.
6. Maximum riser size is 2
1
/
2
-in. diameter. If larger sizes are required, please consult the factory.
7. Expansion loops in hot water heating circuits as required.
8. A 9-in. x 2
1
/
4
-in. slot is provided in the inside back panel for coil connection penetration to permit expansion and
contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.
9. Drawing is pictorial (see unit arrangements for actual supply and return air orientation).
10. 42SHA available in front return only.
11. All dimensions are in inches.
a42-4303
**Factory-Installed.
††Field-Installed.
ITEM DESCRIPTION QTY
1 Full Riser Chase
1
2 Electrical Knockouts 1
3 3-in. Expansion Section 3/5
4 Strip Heater (Optional) 1
5 Limit Switch**†† (Optional) 1
6
1
/
2
-in. Isolation Ball Valves**
2/4
7 Flexible Drain Tube/P-Trap 1
8 Drain Pan 1
9 Coil
1
/
2
-in. OD Tube
1
10 Filter, Throwaway, 1-in.** 1
11 Air Vent, Manual 1
12 Control Box 1
13 Cabinet Camloc
®
Fasteners 2
14 3-Speed Switch (Optional)
1
15 Electrical Access Panel 1
16 Riser, Supply and Return (Copper) 2/4
17 Riser, Drain (Copper) 1
18 Return Air Panel 1
19 Motor, 3-Speed, PSC 1
20 Blower 1
21 Thermostat (Optional) 1
22 Hinged Control Access Door 1
23 Double Deflection Steel Core Grille Assembly 1
LEGEND
CR Cold Water Return
CS Cold Water Supply
D— Drain
HR Hot Water Return
HS Hot Water Supply
R— Return
S—Supply