RFQ 11332 Question and Answers
1. Will the vendor be responsible for the platform for the new units to set on? No GRDA
will take care of the platform.
2. Who will be responsible for removing the ceiling? GRDA will remove the ceiling.
3. Will there need to be new refrigeration lines? Yes
4. Will GRDA provide lifts? No
5. What is the model number of the current units? Carrier Model # 40RM-008--B600HC
Also attached are documents regarding the current units. There is also a link below.
http://www.carrier.com.ph/brands/pdf/17023a30-335d-4647-aa55-43d3512abe1c.pdf
Seitenansicht 0
1 2 3 4 5 6 ... 48 49

Inhaltsverzeichnis

Seite 1

RFQ 11332 Question and Answers 1. Will the vendor be responsible for the platform for the new units to set on? No GRDA will take care of the platfor

Seite 2 - Service Instructions

9LEGENDTXV — Thermostatic Expansion ValveNOTES:1. Dimensions in [ ] are in millimeters.2. Direction of airflow.3. Recommended clearance: • Rea

Seite 3

10LEGENDTXV — Thermostatic Expansion ValveNOTES:1. Dimensions in [ ] are in millimeters.2. Direction of airflow.3. Recommended clearance: • R

Seite 4

11LEGENDTXV — Thermostatic Expansion ValveNOTES:1. Dimensions in [ ] are in millimeters.2. Direction of airflow.3. Recommended clearance: • R

Seite 5

1240RM – Commercial PackagedAir Handler40RM – 016 – – B 5 0 1 GCCooling Coil –– Direct ExpansionQ – Direct Expansion for Heat

Seite 6

13Unit Positioning — The unit can be mounted on thefloor for vertical application with return air entering the face ofthe unit and supply air discharg

Seite 7

14NOTE: Dimensions in [ ] are millimeters.Fig. 5 — Preferred Suspension TechniqueUNIT SIZES 007-012UNIT SIZES 014-024UNIT SIZES 028,034OVERHEAD SUSPEN

Seite 8

15*Must be enlarged from 11/8 in. to 13/4 inches.NOTE: Access hole knockouts 1-4 are factory-supplied.Fig. 6 — Refrigerant and Chilled Water Piping Ac

Seite 9

16RETURNAIRSUBBASEACCESSORY15 DIAMSMIN40RMQ024UNITELECTRICHEATERACCESSORY24 VCONTROLWIREBULB CAPILLARYTUBES10 DIAMSMINCONDENSATEDRAIN8 DIAMSMINDISCONN

Seite 10

17Table 2 — Factory-Installed Nozzle and Distributor Data*Feeder tube size is 1/4 in. (6.35 mm).NOTE: Hot gas bypass applications require field-suppli

Seite 11

18Table 3 — Fitting Requirements (cont)*See Fig. 6 for access hole location by number.†Fittings are listed in order from header or tee stub connection

Seite 12

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Seite 13 - Fig. 3 — Foam Block Location

19Table 3 — Fitting Requirements (cont)*See Fig. 6 for access hole location by number.†Fittings are listed in order from header or tee stub connection

Seite 14 - Refrigerant Piping —

20Condensate Drain — Install a trapped condensate drainline to unit connection as shown in Fig. 13. The unit drain con-nection is a PVC stub. See Fig.

Seite 15 - OVERHEAD SUSPENSION ACCESSORY

21Power Supply and Wiring — Check the unit dataplate to ensure that available power supply matches electricalcharacteristics of the unit. Provide a di

Seite 16 - HORIZONTAL INSTALLATION

22Table 4 — Electrical Data, Standard MotorsSee Legend and Notes on page 23.UNIT V*-PH-HzVOLTAGELIMITSFAN MOTOR POWER SUPPLYHp (kW) FLAMinimumCircuit

Seite 17 - Heat Pump Systems

23Table 5 — Electrical Data, Alternate MotorsLegend and Notes For Tables 4 and 5LEGEND*Motors are designed for satisfactory operation within 10% of no

Seite 18

24Table 6 — Fan Contactor Coil DataConnecting Ductwork — Refer to the Carrier SystemDesign Manual for the recommended design and layout ofductwork. F

Seite 19

25START-UPBefore starting unit, check the following and correct as nec-essary: • Is unit solidly supported?• Is fan adjusted for speed and pulley alig

Seite 20 - Chilled Water Piping —

26Centering Fan Wheel — If fan and fan shaft assemblyare not properly centered, blades may scrape against scroll ormay create an objectionable whistli

Seite 21 - Fan Motors and Drives —

27Fan Pulley Alignment — Align as follows:1. Loosen setscrews on pulleys.2. Align pulleys visually and tighten setscrews on fan pulleyto lock it in pl

Seite 22 - Power Supply and Wiring —

28Table 8A — Fan Motor Data, Standard Motor — EnglishLEGENDNEMA — National Electrical Manufacturers AssociationTable 8B — Fan Motor Data, Alternate Mo

Seite 23

24. This installation must conform with local building codesand with the NEC (National Electrical Code) or ANSI(American National Standards Institute)

Seite 24 - IMPORTANT:

29Table 8C — Fan Motor Data, Standard Motor — SILEGENDNEMA — National Electrical Manufacturers AssociationTable 8D — Fan Motor Data, Alternate Motor —

Seite 25 - Return-Air Filters —

30Table 9A — Standard Drive Data, 60 Hz — English*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.Table

Seite 26 - Fan Shaft Bearings —

31Table 9C — High-Static Drive Data, 60 Hz — English*Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 7 in. and result

Seite 27 - Fan Rotation —

32Table 9E — Medium-Static Drive Data, 50 Hz — EnglishTable 9F — High-Static Drive Data, 50 Hz — English*It is possible to adjust drive so that fan sp

Seite 28

33Table 9G — Standard Drive Data, 60 Hz — SI*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.Table 9H —

Seite 29

34Table 9I — High-Static Drive Data, 60 Hz — SI*Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 178 mm andresulting f

Seite 30

35Table 9K — Medium-Static Drive Data, 50 Hz — SITable 9L — High-Static Drive Data, 50 Hz — SI*It is possible to adjust drive so that fan speed exceed

Seite 31

36Table 10A — 40RM,RMQ Standard Fan Performance Data —0.0-2.4 in. wg External Static Pressure — EnglishSee Legend and Notes on page 44.UNITAIRFLOW(Cfm

Seite 32

37Table 10A — 40RM,RMQ Standard Fan Performance Data —0.0-2.4 in. wg External Static Pressure — English (cont)See Legend and Notes on page 44.UNITAIRF

Seite 33

38Table 10B — 40RM,RMQ Standard Fan Performance Data —0-600 kPa External Static Pressure — SISee Legend and Notes on page 44.UNITAIRFLOW(L/s)EXTERNAL

Seite 34

3Table 1A — 40RM Physical Data, English — Cooling UnitsLEGEND*Units are shipped without refrigerant charge.UNIT 40RM 007 008 012 014 016 024 028 034NO

Seite 35

39Table 10B — 40RM,RMQ Standard Fan Performance Data —0-600 kPa External Static Pressure — SI (cont)See Legend and Notes on page 44.UNITAIRFLOW(L/s)EX

Seite 36

40Table 10C — 40RM High Capacity Fan Performance Data —0.0-2.4 in. wg External Static Pressure — EnglishSee Legend and Notes on page 44.UNITAIRFLOW(Cf

Seite 37

41Table 10C — 40RM High Capacity Fan Performance Data —1.0-2.4 in. wg External Static Pressure — English (cont)See Legend and Notes on page 44.UNITAIR

Seite 38

42Table 10D — 40RM High Capacity Fan Performance Data —0-600 kPa External Static Pressure — SISee Legend and Notes on page 44.UNITAIRFLOW(L/s)EXTERNAL

Seite 39

43Table 10D — 40RM High Capacity Fan Performance Data —0-600 kPa External Static Pressure — SI (cont)See Legend and Notes on page 44.UNITAIRFLOW(L/s)E

Seite 40

44Legend and Notes for Tables 10A and 10CLEGENDNOTES:1. Maximum allowable fan speed is 1100 rpm for unit sizes 028 and034; 1200 rpm for all other size

Seite 41

45Replacing Filters — Filters can be removed and in-stalled from either side of the unit. Install new filters in unitsthat have one fan as follows:1.

Seite 42

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Seite 43

START-UP CHECKLIST(SPLIT SYSTEMS WITH 40RM/RMQ/RMS UNITS)I. PRELIMINARY INFORMATIONOUTDOOR: MODEL NO. _________________________SERIAL NO. ____________

Seite 44

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Seite 45

4Table 1B — 40RMQ Physical Data, English — Heat Pump UnitsLEGEND*Units are shipped without refrigerant charge.UNIT 40RMQ 008 012 016 024 028NOMINAL CA

Seite 46 - RETAINER

5Table 1C — 40RMS Physical Data, English — Chilled Water UnitsUNIT 40RMS 008 010 012 014 016 024 028 034NOMINAL CAPACITY (Tons)71/281/210 121/215 20 2

Seite 47 - Ta b 3 c 2 e

6Table 1D — 40RM Physical Data, SI — Cooling UnitsLEGEND*Units are shipped without refrigerant charge.UNIT 40RM 007 008 012 014 016 024 028 034NOMINAL

Seite 48 - II. PRE-START-UP

7Table 1E — 40RMQ Physical Data, SI — Heat Pump UnitsLEGEND*Units are shipped without refrigerant charge.UNIT 40RMQ 008 012 016 024 028NOMINAL CAPACIT

Seite 49 - III. START-UP

8Table 1F — 40RMS Physical Data, SI — Chilled Water UnitsUNIT 40RMS 008 010 012 014 016 024 028 034NOMINAL CAPACITY (kW)26 29 35 43 52 70 87 105OPERAT

Kommentare zu diesen Handbüchern

Keine Kommentare