EACA
Electronic Air Cleaner
Sizes 0014, 0020, & 2020
Manual for:
Installation • Operation • Maintenance
CAUTION: Read installation instructions and rules carefully for safe operation.
Exercisetheusualprecautionswhenworkingwithhighvoltage.
Form# EACA-1SI/IIEACA-14-1 Date 07/02
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - Manual for:

EACAElectronic Air CleanerSizes 0014, 0020, & 2020Manual for:Installation • Operation • MaintenanceCAUTION: Read installation instructions and rul

Seite 2

8Common Questions and AnswersQ. Why isn't my air cleaner cleaning my air?A. The air cleaner is most likely working just like it was designed.Howe

Seite 3

9Q. What if I no longer hear any popping or zapping noises coming frommy unit? Is it still cleaning the air?A. If the zapping noises stop and the air

Seite 4

10MAINTENANCE OF YOUR ELECTRONIC AIR CLEANERWARNING :Handle ionizing-collector cells with care as platescan be sharp and cause injury if not handled p

Seite 5

11To wash cells and prefilter(s)To replace cells in air cleanerWe suggest that you follow the instructions below to properly andthoroughly clean your

Seite 6

12COMMON TROUBLESHOOTING TECHNIQUESSYMPTOM POSSIBLE CAUSES CORRECTIVE ACTIONBroken or loose ionizing wire(s) Remove broken or loose wire andreplace wi

Seite 7

13Dimensions are the same for both models with and without Air Flow Sensors installedUNIT DIMENSIONS - All dimensions in inches (mm)EACAABCDEFGInches

Seite 8

WARNINGOnly a trained, experienced servicemanshould install this electronic air cleaner.A thorough checkout of the unit installationshould be complete

Seite 9

15TECHNICAL SPECIFICATIONS(Specifications subject to change without notice.)MODEL NUMBER-EACA 0014 0020 2020DIMENSIONS (IN) 20 1/4 x 7 1/8 x 24 7/8 24

Seite 10

16TYPICAL MOUNTING POSITIONSShaded illustrations are for positioning use onlyBASEMENT FURNACE(LOWBOY)Mounted horizontally in returnplenum - just above

Seite 11

17PLANNING THE INSTALLATIONTypical Mounting Positions,TransitionsApplicationInstallation RequirementsAir ConditioningHumidifiersOutdoor AirThe air cle

Seite 12

Table of Contents PageList of figures PageSafetyConsiderations&Introduction1Unitspecifications2Facts you should know about your new Electronic Air

Seite 13

Atomizing HumidifiersSheet Metal InstallationTransitionsOutdoor AirTurning VanesIf an atomizing humidifier is installed, it must be mounted downstream

Seite 14

19SELECT LOCATION FOR AIR CLEANERUNIT DIMENSIONS.DIRECTION OF AIR FLOW THROUGH THE AIR CLEANERRemember to select a location that is readily accessible

Seite 15

20INSTALLATIONCAUTION: Only a trained, experienced serviceman shouldinstall this electronic air cleaner. The power supply should beremoved before inst

Seite 16

217. Locate the cabinet in the cold air return duct so that all of the return airflows through the unit (Figure 6). If the furnace and air cleaner ope

Seite 17 - TECHNICAL SPECIFICATIONS

22ELECTRICAL INSTALLATIONAll wiring must comply with applicable local and national codes.CAUTION:Be sure all incoming power is OFF before beginning an

Seite 18 - TYPICAL MOUNTING POSITIONS

23SYSTEM CHECKOUTWARNING: The following procedures should be conducted by aqualified HVAC contractor or repair person ONLY. These procedureswill expos

Seite 19

TROUBLESHOOTINGCAUTION:• These procedures should only be attempted by a qualified HVACtechnician or electrician.• Risk of personal injury could occur

Seite 20

25PRIMARY CIRCUIT WITH FURNACE BLOWER OPERATINGIf there is supply line voltage at the connections and no input voltage to thepower supply, the outage

Seite 21

26SECONDARY CIRCUITIONIZING-COLLECTING CELLNOTE:The cell is electrically energized through a contact terminal located at the top centerof the cell. Th

Seite 22

27CHECKING THE POWER SUPPLYNOTE:If the output light remains out with the collector cells removed from thecabinet, the power supply is defective. Speci

Seite 23

NOTE:DANGER, WARNING, CAUTION.DANGERWARNING couldCAUTION wouldNOTERead the entire instruction manual before starting the installation.Safety Considera

Seite 24 - Figure 8

289. If no voltage is present, remove the second cell. Install cell number oneand measure voltage as described above. If voltage is present, thesecond

Seite 25

29TROUBLE SHOOTING THE DUCT MOUNT ELECTRONIC AIR CLEANERNoIs the unit operating? Is the furnace blower on?YesIs input AC power available?YesIs the saf

Seite 26

30WARNING:The following steps will expose hazardous live parts. Disconnect power between checksand proceed carefully.1. Replace any blown fuses and re

Seite 27

31EACA

Seite 28

32REF. DESCRIPTION NO..1. Power Tray Assembly (W/ AFS) 120V1A. Power Tray Assembly (W/ AFS) 240V1B. Power Tray Assembly (W/O AFS)120V2. High Frequency

Seite 29

WarrantyTwo-Year Limited WarrantyFive-Year Limited Warranty on Power SupplyTHE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:- This Product is warranted to

Seite 30

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Form

Seite 31

INTRODUCTIONThis electronic air cleaner is technically known as a two-stage electrostaticprecipitator. The air cleaner is designed to remove airborne

Seite 32

3UNIT SPECIFICATIONSCabinetIonizing-Collector CellsPrefiltersPower Tray AssemblyAir Flow Sensor (AFS)How to Identify Which Air Cleaner Model you ownTh

Seite 33

4FACTS YOU SHOULD KNOW ABOUT YOUR NEWELECTRONIC AIR CLEANERDusting and "White Dust"OzoneYour new Electronic Air Cleaner will efficiently cle

Seite 34 - EACA PARTS LIST

5How the Air Flow Sensor Works (available on specific models)The electronic AFS was designed to provide an efficient and reliable methodof controlling

Seite 35 - Warranty

6High Altitude OperationBecause the air is less dense at higher altitudes, there is a possibility ofnuisance arcing. The homeowner can quickly and eas

Seite 36

7REPLACING THE IONIZING WIRESIonizing wire breakage is minimal because of the constant tension designand fixed location of the ionizing wire supports.

Kommentare zu diesen Handbüchern

Keine Kommentare