PRODUCT DATA (cont)
EXPANDED RATINGS DATA
COOLING PERFORMANCE — 52SC, SE, SQ 7000 AND 9000 BTU MODELS
(230 AND 265 V)
ALL 7000 NOMINAL BTUH MODELS
Evaporator entering air temp. — 80 F Evap. air — 280 CFM
TEMP. (F) AIR ENT.
COND. (40% RH)
EVAP. AIR — EWB (F)
57.00 62.00 67.00 72.00
80
MBtuh 7.11 7.12 7.86 8.79
kW 0.58 0.58 0.57 0.57
I 2.06 2.06 2.02 1.98
85
MBtuh 6.92 6.94 7.64 8.55
kW 0.61 0.61 0.60 0.59
I 2.17 2.16 2.12 2.08
90
MBtuh 6.74 6.73 7.40 8.29
kW 0.64 0.64 0.63 0.62
I 2.28 2.29 2.23 2.20
95
MBtuh 6.56 6.62 7.17 8.02
kW 0.66 0.67 0.65 0.65
I 2.39 2.41 2.34 2.32
100
MBtuh 6.33 6.32 6.88 7.77
kW 0.69 0.70 0.68 0.67
I 2.53 2.53 2.47 2.44
105
MBtuh 6.11 6.12 6.59 7.51
kW 0.73 0.72 0.71 0.70
I 2.66 2.65 2.61 2.56
110
MBtuh 5.90 5.90 6.32 7.20
kW 0.75 0.75 0.74 0.73
I 2.79 2.78 2.74 2.70
115
MBtuh 5.66 5.67 6.03 6.86
kW 0.79 0.78 0.77 0.77
I 2.92 2.92 2.87 2.85
ALL 9000 NOMINAL BTUH MODELS
Evaporator entering air temp. — 80 F Evap. air — 300 CFM
TEMP. (F) AIR ENT.
COND. (40% RH)
EVAP. AIR — EWB (F)
57.00 62.00 67.00 72.00
80
MBtuh 8.81 9.00 9.69 10.00
kW 0.81 0.80 0.79 0.77
I 5.76 5.72 5.60 5.38
85
MBtuh 8.70 8.86 9.59 10.00
kW 0.84 0.84 0.83 0.81
I 6.09 6.12 5.96 5.78
90
MBtuh 8.54 8.70 9.47 9.99
kW 0.88 0.88 0.87 0.85
I 6.47 6.47 6.36 6.13
95
MBtuh 8.39 8.54 9.34 9.96
kW 0.92 0.92 0.91 0.88
I 6.84 6.83 6.76 6.48
100
MBtuh 8.19 8.30 9.16 9.86
kW 0.96 0.96 0.95 0.93
I 7.16 7.15 7.11 6.90
105
MBtuh 8.00 8.06 8.97 9.77
kW 0.99 0.99 0.99 0.98
I 7.48 7.47 7.47 7.32
110
MBtuh 7.80 7.82 8.75 9.59
kW 1.03 1.03 1.03 1.02
I 7.79 7.79 7.79 7.71
115
MBtuh 7.60 7.59 8.52 9.39
kW 1.07 1.07 1.07 1.07
I 8.09 8.11 8.09 8.07
COOLING PERFORMANCE — 52SC, SE, SQ 12,000 AND 14,000 BTU MODELS
(230 AND 265 V)
ALL 12,000 NOMINAL BTUH MODELS
Evaporator entering air temp. — 80 F Evap. air — 370 CFM
TEMP. (F) AIR ENT.
COND. (40% RH)
EVAP. AIR — EWB (F)
57.00 62.00 67.00 72.00
80
MBtuh 11.10 11.70 13.40 15.30
kW 1.15 1.15 1.16 1.16
I 7.63 7.63 7.70 7.66
85
MBtuh 10.70 11.30 12.90 14.80
kW 1.20 1.20 1.21 1.21
I 8.04 8.04 8.13 8.11
90
MBtuh 10.30 10.70 12.40 14.30
kW 1.25 1.25 1.26 1.26
I 8.50 8.48 8.57 8.54
95
MBtuh 9.92 10.20 11.80 13.80
kW 1.31 1.30 1.31 1.31
I 8.96 8.93 9.00 8.96
100
MBtuh 9.51 9.66 11.30 13.20
kW 1.36 1.35 1.36 1.36
I 9.38 9.35 9.39 9.43
105
MBtuh 9.11 9.13 10.70 12.50
kW 1.41 1.41 1.41 1.42
I 9.79 9.78 9.78 9.89
110
MBtuh 8.71 8.71 10.10 11.90
kW 1.46 1.46 1.46 1.48
I 10.20 10.20 10.10 10.30
115
MBtuh 8.32 8.24 9.46 11.20
kW 1.51 1.52 1.51 1.53
I 10.50 10.60 10.60 10.70
LEGEND
EWB — Entering Wet Bulb
I—Compressor Current Amps
kW — Total Power
MBtuh — Total Cooling Capacity
RH — Relative Humidity
ALL 14,000 NOMINAL BTUH MODELS
Evaporator entering air temp. — 80 F Evap. air — 320 CFM
TEMP. (F) AIR ENT.
COND. (40% RH)
EVAP. AIR — EWB (F)
57.00 62.00 67.00 72.00
80
MBtuh 11.90 13.10 14.10 14.90
kW 1.41 1.38 1.34 1.31
I 7.89 7.71 7.49 7.28
85
MBtuh 11.70 12.90 13.90 14.90
kW 1.48 1.45 1.41 1.37
I 8.28 8.11 7.87 7.67
90
MBtuh 11.40 12.60 13.70 14.70
kW 1.53 1.52 1.48 1.44
I 8.64 8.55 8.28 8.06
95
MBtuh 11.20 12.40 13.50 14.50
kW 1.59 1.59 1.55 1.50
I 9.00 8.99 8.70 8.44
100
MBtuh 10.90 12.00 13.20 14.20
kW 1.65 1.66 1.62 1.57
I 9.40 9.42 9.19 8.88
105
MBtuh 10.70 11.70 13.00 13.90
kW 1.72 1.72 1.70 1.64
I 9.79 9.85 9.67 9.32
110
MBtuh 10.40 11.30 12.70 14.00
kW 1.78 1.79 1.78 1.73
I 10.20 10.30 10.20 9.89
115
MBtuh 10.10 11.00 12.50 14.10
kW 1.85 1.85 1.86 1.82
I 10.70 10.70 10.80 10.50
34