Carrier 38YCA Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
Fig. 7—38YCA042-060 460v, 3 Phase, 60 Hertz
A93464
OF2
YEL
BRN
YEL BLK
YEL
BLK BLU BLU or YEL
BLU or YEL
BRN
YEL
90
50
30
TEST
CTD
C
C
DFT
T1
T2
Y
O
R
BLK
or
ORN
BLK
or
ORN
RVS
DFT
CB
OF1
ORNBLK RED
YEL WHT
C Y O R E L G
INDOOR UNIT
TERMINAL BLOCK
INDOOR THERMOSTAT (NOTE #5)
DR
LPS
DTS HPS
LOGIC
LOGIC
C Y O W2 R
CONNECTION DIAGRAM
W2 W3
C Y O R E L GW2
W2
RVS
C
DR
R
0 0
R
Y Y
C
DFT
DFT
LOGIC
LOGIC
DR
LPS
DTS HPS
T1
CTD
T2 C
CONT
SCHEMATIC DIAGRAM
(LADDER FORM)
NOTES:
1. COMPRESSOR AND FAN MOTOR FURNISHED
WITH INHERENT THERMAL PROTECTION.
2. TO BE WIRED IN ACCORDANCE WITH
NATIONAL ELECTRIC CODE (N.E.C.)
AND LOCAL CODES.
3. N.E.C. CLASS 2, 24 V CIRCUIT, MIN. 40 VA 
REQUIRED.
4. USE COPPER CONDUCTORS ONLY FROM
DISCONNECT TO UNIT.
5. MUST USE THERMOSTAT AND SUB-BASE
AS STATED IN PRE-SALE LITERATURE.
6. IF INDOOR SECTION HAS A TRANSFORMER
WITH A GROUNDED SECONDARY, CONNECT
THE GROUNDED SIDE TO C ON THE
CIRCUIT BOARD.
7. IF ANY OF THE ORIGINAL WIRE, AS
SUPPLIED, MUST BE REPLACED, USE THE
SAME OR EQUIVALENT WIRE.
8. CHECK ALL ELECTRICAL CONNECTIONS
INSIDE CONTROL BOX FOR TIGHTNESS.
9. DO NOT ATTEMPT TO OPERATE UNIT UNTIL
SERVICE VALVES HAVE BEEN OPENED.
10.WHEN DTS, LPS, AND HPS ARE NOT
REQUIRED, A JUMPER WILL BE INSTALLED
BETWEEN Y AND T1 ON THE DEFROST
BOARD.
11.IT IS IMPERATIVE TO CONNECT 30 FIELD 
POWER TO UNIT WITH CORRECT PHASING.
WRONG PHASING WILL CAUSE REVERSE
ROTATION OF SCROLL COMPRESSOR
WHICH WILL RESULT IN REDUCED CURRENT
DRAW; ELEVATED NOISE LEVEL AND 
IMPROPER OPERATION. IF ROTATION IS 
REVERSED, SIMPLY INTERCHANGE ANY 
TWO OF THE THREE POWER CONNECTIONS 
ON THE FIELD SIDE.
90
50
30
TEST
FIELD SELECTED TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)
TEST POINTS, FIELD SPEED UP CYCLE
HEAT CYCLE:
50 MIN. ACCELERATED TO 12 SEC.
90 MIN. ACCELERATED TO 21 SEC.
30 MIN. ACCELERATED TO 7 SEC.
DEFROST CYCLE: 10 MIN. ACCELERATED TO 2 SEC.
- LEGEND -
FACTORY POWER WIRING
FIELD POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
CONDUCTOR ON CIRCUIT BOARD
COMPONENT CONNECTION
1
/4 - INCH QUICK CONNECT
TERMINALS
FIELD SPLICE
JUNCTION
CAPACITOR (RUN)
CRANKCASE HEATER
COMPRESSOR
COMPRESSOR TIME DELAY
CONTACTOR
CIRCUIT BOARD
DEFROST THERMOSTAT
DEFROST RELAY AND CIRCUITRY
DISCHARGE TEMP. SWITCH
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
OUTDOOR FAN MOTOR
OUTDOOR FAN RELAY
REVERSING VALVE SOLENOID
RVS
HPS
CAP
CH
COMP
CTD
CONT
CB
DFT
DR
DTS
OFM
OFR
LPS
23
460 30
POWER
SUPPLY
ALERT!
SEE NOTE #11
EQUIP
GND
L1
L3
11
21
13
OFM
CH
COMP
T1
T2
T3
CAP
CONT
YEL
BRN
YEL
BLK
YEL
BLU
L2
RED
or BLK
RED
or BLK
OFR
BLK
BLK
BLK
BLK
BLK
or
PNK
BLK or PNK
13
EQUIP
GND
L1
11 21
COMP
CONT
23
OFM
CAP
L3
CONT
L2
T1
T2
T3
CH
1 3
OFR
OFR
OF2
DR
1 3
BRN
OF1
BLK
MAY BE FACTORY OR FIELD
INSTALLED
321011 - 401 REV. B
THIS DEFROST CONTROL BOARD CONTAINS
A FIVE MINUTE SHORT CYCLE PROTECTOR.
A FIVE MINUTE DELAY WILL OCCUR BETWEEN
COMPRESSOR OFF/ON CYCLES.
N O T E
BLK
7
Seitenansicht 6
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare