Carrier 38YCA Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
Fig. 4—38YCA036 208/230v, 3 Phase, 60 Hertz
A93516
MAY BE FACTORY OR FIELD
INSTALLED
90
50
30
TEST
FIELD SELECTED TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)
TEST POINTS, FIELD SPEED UP CYCLE
HEAT CYCLE:
50 MIN ACCELERATED TO 12 SEC
90 MIN ACCELERATED TO 21 SEC
- LEGEND -
FACTORY POWER WIRING
FIELD POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
CONDUCTOR ON CIRCUIT BOARD
COMPONENT CONNECTION
1
/4 - INCH QUICK CONNECT
TERMINALS
FIELD SPLICE
JUNCTION
CAPACITOR (RUN)
CRANKCASE HEATER
COMPRESSOR
CONTACTOR
CIRCUIT BOARD
DEFROST THERMOSTAT
DEFROST RELAY AND CIRCUITRY
DISCHARGE TEMP SWITCH
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
OUTDOOR FAN MOTOR
REVERSING VALVE SOLENOID
LPS
CAP
CH
COMP
CONT
CB
DFT
DR
DTS
HPS
OFM
RVS
23
OF2
CONT
EQUIP
GND
L1
L3
11
21
13
OFM
BLK
BLK
YEL
BRN
YEL BLK
YEL
BLK BLU BLU or YEL
BLU or YEL
BRN
YEL
90
50
30
TEST
C
C
DFT
T1
Y
O
R
BLK
or
ORN
BLK or PNK
BLK
or
ORN
BLK
or
PNK
RVS
DFT
CB
OF1
ORNBLK RED
YEL WHT
C Y 0 R E L G
INDOOR UNIT
TERMINAL BLOCK
INDOOR THERMOSTAT (NOTE #5)
DR
208/230
30 POWER
SUPPLY
LPS DTS HPS
LOGIC
C Y O W2 R
CONNECTION DIAGRAM
W2 W3
C Y 0 R E L GW2
BLU or YEL
RED or BLK
RED
or
BLK
ALERT!
L2
BLU
SEE NOTE #11
BLK
YEL
COMP
T2
T1
T3
CH
YEL
BRN
YEL
CAP
W2
23
EQUIP
GND
L1
11
21
COMP
CONT
13
OFM
CAP
DR
OF1 OF2
RVS
C
DR
R
0 0
R
Y Y
C
DFT
DFT
LOGIC
DR
LPS
DTS HPS
T1
C
CONT
L2
SCHEMATIC DIAGRAM
(LADDER FORM)
L3
CONT
T1
T2
T3
NOTES:
1. COMPRESSOR AND FAN MOTOR FURNISHED
WITH INHERENT THERMAL PROTECTION.
2. TO BE WIRED IN ACCORDANCE WITH
NATIONAL ELECTRIC CODE (N.E.C.)
AND LOCAL CODES.
3. N.E.C. CLASS 2, 24 V CIRCUIT, MIN
40 VA REQUIRED.
4. USE COPPER CONDUCTORS ONLY FROM
DISCONNECT TO UNIT.
5. MUST USE THERMOSTAT AND SUB-BASE
AS STATED IN PRE-SALE LITERATURE.
6. IF INDOOR SECTION HAS A TRANSFORMER
WITH A GROUNDED SECONDARY, CONNECT
THE GROUNDED SIDE TO "C" ON THE
CIRCUIT BOARD.
7. IF ANY OF THE ORIGINAL WIRE, AS
SUPPLIED, MUST BE REPLACED, USE THE
SAME OR EQUIVALENT WIRE.
8. CHECK ALL ELECTRICAL CONNECTIONS
INSIDE CONTROL BOX FOR TIGHTNESS.
9. DO NOT ATTEMPT TO OPERATE UNIT UNTIL
SERVICE VALVES HAVE BEEN OPENED.
10.WHEN DTS, LPS AND HPS ARE NOT
REQUIRED, A JUMPER WILL BE INSTALLED
BETWEEN Y AND T1 ON THE DEFROST
BOARD.
11.IT IS IMPERATIVE TO CONNECT 30 FIELD
POWER TO UNIT WITH CORRECT PHASING.
WRONG PHASING WILL CAUSE REVERSE
ROTATION OF SCROLL COMPRESSOR
WHICH WILL RESULT IN REDUCED CURRENT
DRAW, ELEVATED NOISE LEVEL AND
IMPROPER OPERATION. IF ROTATION IS
REVERSED, SIMPLY INTERCHANGE ANY
TWO OF THE THREE POWER CONNECTIONS
ON THE FIELD SIDE.
CH
321069-401 REV. A
30 MIN ACCELERATED TO 7 SEC
DEFROST CYCLE: 10 MIN ACCELERATED TO 2 SEC
4
Seitenansicht 3
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare