42VMC---N
GB - 7
ENGLISH
Drilling the hole in the wall for the
connection of the pipes
The pipes can exit the unit to three different directions (see
illustration). For exit to the rear, the wall hole must be made in the
position shown in the illustration.
Drill a 70 or 80 mm diameter hole.
The hole must have a 5-10 mm downward slope towards the
outside. Insert the plastic conduit provided.
Pass the electrical connecting wires through the conduit (see
electrical connections).
Indoors
Outdoors
Condensate drain pipe
For vertical installation
Connect the PVC pipe to the connection on the drain pan.
IMPORTANT:
The outdoor unit is designed to operate without the use of
condensate water to cool the condenser coil.
It is necessary to discharge the condensate directly into
the sewer system, downpipes or to disperse it outside.
Installation: 42VMC 009N - 012N - 014N - 018N - 024N
A Refrigerant connections
B Condensate drain pipe
Ø 80 mm
50 mm
75 mm
Ø 70 / 80 mm
5-10 mm
D
C
B
A
A
B
42VMC---N 009 012 014 018 024
A mm 850 850 1000 1000 1000
B mm 786 786 940 940 940
C mm 237 237 250 250 250
D mm 237 237 285 285 285
For horizontal installation
To allow the condensate drain pipe to correctly come out of the
unit, proceed as follows:
• Remove from suction grille, the part of grille fixed tonguing,
pressing it until tabs is unhooked.
Mount condensate drain pipe cover supplied, fitting it as
necessary. In the event of condensate discharge pump is used
(accessory), the condensate drain pipe can exit together with
the refrigerant pipes.