LEGEND
*Standard unit fitted with optional electric heating elements. Available
with 230-v model units only.
†Standard unit fitted with optional step-up transformer for connection to
a 115-v electrical supply. Electric heat not available in conjunction with
this option.
42WKN UNIT SIZE
STANDARD UNITS
V-Ph-Hz MCA FLA Recommended Fuse (Amps)
08,12 208/230-1-60 0.74 0.65 10
18,20 208/230-1-60 0.99 0.85 10
33,36 208/230-1-60 1.40 1.30 10
42WKN
UNIT SIZE
UNITS WITH OPTIONAL ELECTRIC HEAT* UNITS WITH OPTIONAL STEP-UP TRANSFORMER†
V-Ph-Hz
Electric Heat
Capacity (kW)
MCA FLA
Recommended
Fuse (Amps)
V-Ph-Hz MCA FLA
Recommended
Fuse (Amps)
08,12 208/230-1-60 1.5 8.9 7.2 15 115-1-60 1.5 1.3 10
18,20 208/230-1-60 3.0 19.3 13.9 20 115-1-60 2.0 1.7 10
33,36 208/230-1-60 5.0 28.8 23.1 30 115-1-60 2.8 2.5 10
FLA — Full Load Amps
MCA — Minimum Circuit Amps