FIRE OR EQUIPMENT HAZARD
Failure to follow this warning could result in equipment
damage or fire.
Do not apply 24vac fan powered humidifier (with internal
power supply) direct to indoor unit HUM and COM termi-
nals.
INITIAL POWER-UP
NOTE: Refer to Functional Overview (Fig. 11) to become
familiar with key function buttons such as System On/Off,
Fan, Left-Side and Right-Side buttons, etc. These function
buttons will be used frequently during setup.
SECTION 1 POWER UP SEQUENCE
This section addresses initial power up (or commissioning) of a
new Infinity Control. The User Interface will communicate and
identify all Infinity components in the system. The following is a
typical example for a communicating Variable-Speed Furnace /
Fan Coil with a 2-spd. Air Conditioner / Heat Pump (including
Dual Fuel).
The User Interface display will light up and indicate that it is now
ESTABLISHING COMMUNICATIONS WITH EQUIPMENT
PLEASE WAIT. The User Interface will automatically continue
by SEARCHING FOR INDOOR EQUIPMENT, followed by
SEARCHING FOR OUTDOOR EQUIPMENT (See Figure 15).
Once the indoor and outdoor equipment has been found, the
Installer will be asked to select Accessories. Proceed to Section 4.
Selecting Accessories.
NOTE: If the variable-speed indoor equipment (furnace or fan
coil) cannot be found, the User Interface will display CANNOT
COMMUNICATE WITH INDOOR UNIT. This MUST be
corrected before the initial power up sequence can continue. If
indoor unit is found, but the outdoor unit is not found, OUT-
DOOR UNIT NOT IDENTIFIED will appear. Proceed to the next
section for Outdoor Unit Identification.
SECTION 2 SELECTING OUTDOOR UNIT
If there is no communicating outdoor unit, the screen, shown in
Fig. 16, will appear. Press either Time or Temp +/- buttons to
select AC (air conditioner), HP (heat pump), or None (no unit
installed). Press the right-side button to continue to the next screen.
If you have selected either AC or HP as the outdoor unit type, the
following middle screen will appear (See figure 16). Press either
Time or Temp +/- buttons to select appropriate Btu size of outdoor
unit, then press right side button to continue. If a NIM (Network
Interface Module) is applied for non-communicating two-speed
outdoor equipment, select 1 or 2speed compressor operation , and
press right-side button to continue.
NOTE: Range of Btu selection is limited by the model number of
the indoor unit installed. The Infinity Control will not allow an
outdoor unit size that is not supported by the installed indoor unit.
NOTE: On new system installations, the model and serial number
will be recognized and displayed. On any indoor/outdoor board
replacements, the equipment will be recognized but the exact
model/serial number will not be displayed.
SECTION 3 SELECTING ELECTRIC HEATER
If the indoor unit is a fan coil and the electric heater is not
self-identifying, ELECTRIC HEATER NOT IDENTIFIED will
appear (See figure 17). Press either Time or Temp +/- buttons to
select appropriate size of electric heater installed, then press the
right-side button to continue.
A
B
C
D
A
B
C
D
C
Y
ABCD
Connection
User Interface
1-Spd. AC
Green
Yellow
White
Red
Optional Remote
Room Sensor
HUM
COM
24V
Humidifier
Connection
Y/Y2
S2
S1
OAT
OAT
Sensor
Variable-Speed
Furnace/Fan Coil
Fig. 13Connection Diagram for
Furnace or FE Fan Coil w/1-Spd. AC
A03147
A
B
C
D
A
B
C
D
ABCD
Connection
User Interface
1-Spd. HP
Green
Yellow
White
Red
Optional Remote
Room Sensor
HUM
C
Humidifier
Connection
Y
S2
S1
W2
Y
O
C
R
O
R
W
OAT
OAT
Sensor
Variable-Speed
Fan Coil
Fig. 14Connection Diagram for
FE Fan Coil w/1-Spd. HP
A03148
Fig. 15 Power Up Sequence
A03195
ESTABLISHING
COMMUNICATIONS
WITH EQUIPMENT
PLEASE WAIT
SOFTWARE
VERSION
INDOOR UNIT
SEARCHING FOR
INDOOR EQUIPMENT
WORKING
OUTDOOR UNIT
SEARCHING FOR
OUTDOOR EQUIPMENT
WORKING
Fig. 16Selecting Outdoor Unit
A03196
OUTDOOR UNIT
NOT IDENTIFIED
SELECT TYPE: NONE
NONE, AC, HP
PRESS +/- TO MAKE
SELECTION
CONTINUE
OUTDOOR UNIT
ENTER HEAT PUMP
SIZE 36000 BTU
18000 TO 60000 BTU
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
OUTDOOR UNIT
HEAT PUMP
ENTER NUMBER OF
SPEEDS, 1 or 2: 1
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE