INFINITY™ 96 MODEL 58MVB
DELUXE 4-WAY MULTIPOISE VARIABLE-SPEED
CONDENSING GAS FURNACE
Series 100 Input Rates: 40,000 thru 120,000 Btuh
Product Data
Comfort Heat™ technology,
the ultimate in
heating comfort . . .
The Carrier Infinity™ 96 with Com-
fortHeat™ technology achieves the opti-
mum combination of comfort and
efficency.
The Infinity™ 96 achieves industry-
leading ultra-high efficiency at up to
96.6 percent Annual Fuel Utilization Ef-
ficiency (AFUE). Efficient performance
is enhanced through the variable-speed
design. To maintain ideal comfort, Com-
fortHeat™ technology automatically ad-
justs the heating level, maximizing the
use of low heating levels that produce
near silent furnace operation while meet-
ing the exact heating needs. This unit is
designed to keep the indoor temperature
within 1 degree of the thermostat set-
point. Because it operates in low heat
most of the time, the Infinity™ 96 uses
up to 80% less power than single-capac-
ity furnaces.
In addition to providing ultimate com-
fort, the Infinity™ 96 has a sealed com-
bustion system. This system brings
combustion air to the furnace and vents
flue gases outside the furnace in a safe
manner. Because it is sealed, operational
noise is minimal. A sealed combustion
system also means fewer cold drafts and
less air infiltration.
Quality materials are the key behind the
Infinity™ 96’s outstanding perfor-
mance. Carrier stands behind quality.
We offer lifetime warranty protection*
on the heat exchangers, the heart of the
Infinity™ 96. The rest of the unit is
backed by a limited 5-year warranty.
The Infinity™ 96 is available in 6 heat/
airflow combinations. The unit has a
4-way multipoise design and can be
installed in upflow, downflow, or
A05069
Seitenansicht 0
1 2 3 4 5 6 ... 21 22

Inhaltsverzeichnis

Seite 1 - Product Data

INFINITY™ 96 MODEL 58MVBDELUXE 4-WAY MULTIPOISE VARIABLE-SPEED CONDENSING GAS FURNACESeries 100 Input Rates: 40,000 thru 120,000 BtuhProduct Data Comf

Seite 2 - Infinity™ 96 FEATURES/

1058MVB†† ††† ‡†† ‡†† ††† ‡†† ‡‡†† ††† ‡†† ‡‡‡‡‡†† ††† ‡†† ‡‡‡‡††† ‡†† ‡‡‡‡††† ‡†† ‡‡‡‡‡†‡††

Seite 3

1158MVBDimensionsCOMBUSTION-AIR PIPE FOR NON-DIRECT (1-PIPE) VENT APPLICATION (SIZES 040 THROUGH 120 ONLY)CONCENTRIC VENT (DIRECT VENT/2-PIPE ONLY) (A

Seite 4 - Carrier accessories

1258MVBA05053175⁄16"241⁄2"279⁄16"TYP275⁄8"2911⁄16"TYP3013⁄16"325⁄8"TYP331⁄4"TYPCONDENSAT EDRAIN TRAPLOCATION(A

Seite 5

1358MVBDIMENSIONS (In.)* The plenum should be constructed 1/4-in. smaller in width and depth than the plenum dimensions shown above.FURNACECASINGWIDTH

Seite 6

1458MVBElectrical data* Permissible limits of the voltage range at which the unit will operate satisfactorily. ‡ Length shown is as measured 1 way alo

Seite 7 - REGISTERED QUALITY SYSTEM

1558MVBMaximum Allowable Pipe Length (Ft)ALTITUDEUNIT SIZE(BTUH)DIRECT VENT (2-PIPE) ONLYNON-DIRECT VENT(1-PIPE) ONLYNUMBER OF 90° ELBOWSTerminationTy

Seite 8 - Performance data

1658MVBMaximum Allowable Pipe Length (Ft) ContinuedALTITUDEUNIT SIZE(BTUH)DIRECT VENT (2-PIPE) ONLYNON-DIRECT VENT(1-PIPE) ONLYNUMBER OF 90° ELBOWSTer

Seite 9

1758MVBMaximum Allowable Pipe Length (Ft) ContinuedALTITUDEUNIT SIZE(BTUH)DIRECT VENT (2-PIPE) ONLYNON-DIRECT VENT(1-PIPE) ONLYNUMBER OF 90° ELBOWSTer

Seite 10

1858MVBMAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT)WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT** Pipe length (ft) specified for maximum ven

Seite 11 - Dimensions

1958MVBClearance to combustiblesClearance in inches.Vent clearance tocombustibles 0".This furnace is approved for UPFLOW, DOWNFLOW andHORIZONTAL

Seite 12 - DIMENSIONS (In.)

258MVB horizontal positions covering up to 24 different applications. The Infinity™ 96 can be installed as a Non-Direct vent/1-pipe or Direct vent/2-

Seite 13 - Filter Cabinet

2058MVBTypical installationsBasement — Upflow Application A05064Closet — Downflow Application

Seite 14 - Typical wiring schematic

2158MVBCOMBUSTION–AIR PIPEELECTRONICAIR CLEANERFURNACECONDENSATEDRAINREFRIGERATIONPIPINGAIR CONDITIONINGCOILAIRFLOWVENT PIPEFRONT OF FURNACEA05066DIRE

Seite 15 - See notes on page 17

Copyright 2006 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 Printed in U.S.A. edition date: 01/06Manufacturer reserves the right to cha

Seite 16

358MVB NOTES: 1. The 58MVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory-authorized and li

Seite 17

458MVB Model number nomenclatureCarrier accessories * See notes at end of table. UNIT SIZE040-14 060-14 080-14 080-20 100-20 120-20VENT TERMINATION K

Seite 18

558MVB Carrier accessories * continued UNIT SIZE040-14 060-14 080-14 080-20 100-20 120-20ADVANCED PRODUCT MONITOR (software and hardware to link pc

Seite 19 - Clearance to combustibles

658MVB A93086 CONCENTRIC VENT (DIRECT VENT /2-PIPE ONLY) A concentric vent kit allows vent and combustion-air pipes to terminate through a single exi

Seite 20 - Typical installations

758MVB ® A97152 ELECTRONIC ORMECHANICALAIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expe

Seite 21

858MVBPhysical dataUNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20DIRECT-DRIVE MOTOR Hp (ECM)1/2 1/2 1/2 1 1 1MOTOR FULL LOAD AMPS7.7 7.7 7.7 12.8

Seite 22 - Guide specifications

958MVB†† †††‡††‡†††††‡††‡‡†† †††‡††‡‡‡‡‡†† †††‡††‡‡‡‡†††‡††‡‡‡‡†††‡††‡‡‡‡‡†‡††