INFINITY™ 96 MODEL 58MVBDELUXE 4-WAY MULTIPOISE VARIABLE-SPEED CONDENSING GAS FURNACESeries 100 Input Rates: 40,000 thru 120,000 BtuhProduct Data Comf
1058MVB†† ††† ‡†† ‡†† ††† ‡†† ‡‡†† ††† ‡†† ‡‡‡‡‡†† ††† ‡†† ‡‡‡‡††† ‡†† ‡‡‡‡††† ‡†† ‡‡‡‡‡†‡††
1158MVBDimensionsCOMBUSTION-AIR PIPE FOR NON-DIRECT (1-PIPE) VENT APPLICATION (SIZES 040 THROUGH 120 ONLY)CONCENTRIC VENT (DIRECT VENT/2-PIPE ONLY) (A
1258MVBA05053175⁄16"241⁄2"279⁄16"TYP275⁄8"2911⁄16"TYP3013⁄16"325⁄8"TYP331⁄4"TYPCONDENSAT EDRAIN TRAPLOCATION(A
1358MVBDIMENSIONS (In.)* The plenum should be constructed 1/4-in. smaller in width and depth than the plenum dimensions shown above.FURNACECASINGWIDTH
1458MVBElectrical data* Permissible limits of the voltage range at which the unit will operate satisfactorily. ‡ Length shown is as measured 1 way alo
1558MVBMaximum Allowable Pipe Length (Ft)ALTITUDEUNIT SIZE(BTUH)DIRECT VENT (2-PIPE) ONLYNON-DIRECT VENT(1-PIPE) ONLYNUMBER OF 90° ELBOWSTerminationTy
1658MVBMaximum Allowable Pipe Length (Ft) ContinuedALTITUDEUNIT SIZE(BTUH)DIRECT VENT (2-PIPE) ONLYNON-DIRECT VENT(1-PIPE) ONLYNUMBER OF 90° ELBOWSTer
1758MVBMaximum Allowable Pipe Length (Ft) ContinuedALTITUDEUNIT SIZE(BTUH)DIRECT VENT (2-PIPE) ONLYNON-DIRECT VENT(1-PIPE) ONLYNUMBER OF 90° ELBOWSTer
1858MVBMAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT)WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT** Pipe length (ft) specified for maximum ven
1958MVBClearance to combustiblesClearance in inches.Vent clearance tocombustibles 0".This furnace is approved for UPFLOW, DOWNFLOW andHORIZONTAL
258MVB horizontal positions covering up to 24 different applications. The Infinity™ 96 can be installed as a Non-Direct vent/1-pipe or Direct vent/2-
2058MVBTypical installationsBasement — Upflow Application A05064Closet — Downflow Application
2158MVBCOMBUSTION–AIR PIPEELECTRONICAIR CLEANERFURNACECONDENSATEDRAINREFRIGERATIONPIPINGAIR CONDITIONINGCOILAIRFLOWVENT PIPEFRONT OF FURNACEA05066DIRE
Copyright 2006 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 Printed in U.S.A. edition date: 01/06Manufacturer reserves the right to cha
358MVB NOTES: 1. The 58MVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory-authorized and li
458MVB Model number nomenclatureCarrier accessories * See notes at end of table. UNIT SIZE040-14 060-14 080-14 080-20 100-20 120-20VENT TERMINATION K
558MVB Carrier accessories * continued UNIT SIZE040-14 060-14 080-14 080-20 100-20 120-20ADVANCED PRODUCT MONITOR (software and hardware to link pc
658MVB A93086 CONCENTRIC VENT (DIRECT VENT /2-PIPE ONLY) A concentric vent kit allows vent and combustion-air pipes to terminate through a single exi
758MVB ® A97152 ELECTRONIC ORMECHANICALAIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expe
858MVBPhysical dataUNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20DIRECT-DRIVE MOTOR Hp (ECM)1/2 1/2 1/2 1 1 1MOTOR FULL LOAD AMPS7.7 7.7 7.7 12.8
958MVB†† †††‡††‡†††††‡††‡‡†† †††‡††‡‡‡‡‡†† †††‡††‡‡‡‡†††‡††‡‡‡‡†††‡††‡‡‡‡‡†‡††
Kommentare zu diesen Handbüchern