SECTION 8
SERVICE
WARNING
Advance microprocessor equipped units
may start automatically at any time the Main
Power switch is not in the OFF position.
Also, the unit may be fitted with two way
communication equipment that will allow
starting of the unit from a remote location
even though the switch is in the OFF posi-
tion.
WARNING
Be aware of HIGH VOLTAGE supplied at the
power plug or from the generator. When
performing service or maintenance proced-
ures: ensure any two way communication is
disabled in accordance with the manufac-
turer’s instruction, ensure the Main Power
Switch is in the OFF position and, whenever
practical, disconnect the high voltage
source, lockout/tagout the receptacle and
disconnect the negative battery connec-
tion. NEVER dis-assemble the generator:
HIGH MAGNETIC FIELD INSIDE! This field
can interfere with cardiac implants such as
pacemakers and defibrillators.
WARNING
Disconnect batteries before doing any elec-
trical welding on unit or chassis to which
unit is attached (trailer, container, rail car,
metal building, etc).
CAUTION
Unit uses R404A and POE oil. The use of in-
ert gas brazing procedures is mandatory for
all Carrier Transicold refrigeration units;
otherwise compressor failure will occur.
For more information Refer to Technical
Procedure 98-50553-00 Inert Gas Brazing
8.1 SECTION LAYOUT
Service procedures are presented herein under the
following major sections:
S Scheduled Maintenance - Section 8.2
S Pretrip Inspection - Section 8.3
S External Surface Service (grille, surround, doors and
display & keypad assembly) - Section 8.4, beginning
on page 85
S Engine And Engine Related Systems Service- Sec-
tion 8.5, beginning on page 87
S Refrigerant System Service - Section 8.6, beginning
on page 814
S Compressor and Unloader Service - Section 8.7, be-
ginning on page 820
S Refrigerant System Component Service - Section
8.8, beginning on page 826
S Electrical System Component Service - Section 8.9,
beginning on page 832.
Refer to the Table Of Contents to locate specific topics.
8.2 SCHEDULED MAINTENANCE
For the most reliable operation and for maximum life,
your unit requires regular maintenance. This includes oil
and filter changes, fuel and air cleaner replacement,
coolant replacement and pretrip inspections.
Maintenance is to be performed in accordance with the
procedures provided in Table 81.
8.3 PRE TRIP INSPECTION
Pre trip inspection should be performed before every trip
and at regular maintenance intervals. Pre trip
procedures are provided in Table 82.