Product Data
40MBFQ
Floor Console Ductless System
Sizes 09 to 12
NOTE: Image for illustration purposes only. Actual model may
differ slightly.
INDUSTRY LEADING
FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN
BUDGET LIMITS, ENERGY SAVINGS AND
COMFORT.
The 40MBFQ series ductless system are a matched combination
of an outdoor condensing unit and an indoor fan coil unit
connected only by refrigerant tubing and wires.
The fan coil is mounted on the floor, against the wall. This
selection of fan coils permits creative solutions to design problems
such as:
S Add−ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system.
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S Historical renovations or any application where
preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is
impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Product Data

Product Data40MBFQFloor Console Ductless SystemSizes 09 to 12NOTE: Image for illustration purposes only. Actual model maydiffer slightly.INDUSTRY LEAD

Seite 2

10FAN AND MOTOR SPECIFICATIONSSYSTEM SIZE9 12(208-230V) (208-230V)Indoor fanmaterial AS ASType LX-370*80*8-7JN LX-370*80*8-7JNDiameter inch 14.6 14.6H

Seite 3 - MODEL NUMBER NOMENCLATURE

11WIRING DIAGRAMXS1-XS5XP1-XP5CN1-CN20RT2 RT1XT1M1FAN 4-WAY TERMINALROOM TEMPERATUREPIPE TEMPERATURECONNECTORSCONNECTORSP.C BOARD SOCKETSWIRING DIAGR

Seite 4 - ACCESSORIES

12GUIDE SPECIFICATIONSINDOOR WALL−MOUNTED FLOOR CONSOLE DUCTLESS UNITSSize Range: 3/4 to 1 Ton Nominal Cooling and Heating CapacityModel Number: 40MBF

Seite 5 - DIMENSIONS − INDOOR

2LOW SOUND LEVELSWhen noise is a concern, the ductless systems are the answer. Theindoor units are whisper quiet. There are no compressors indoors,eit

Seite 6 - CLEARANCES − INDOOR

3MODEL NUMBER NOMENCLATUREQF-SYSTEM TYPEQ = HEAT PUMPINDOOR FAN COIL TYPEF= FLOOR CONSOLENOT USEDINDOOR UNIT40 MB 30940= FAN COIL UNITMB = MODELVOLTAG

Seite 7 - APPLICATION DATA

4STANDARD FEATURES AND ACCESSORIESEase Of InstallationMounting Brackets SLow Voltage Controls SComfort FeaturesMicroprocessor Controls SWired Remote C

Seite 8 - WIRELESS REMOTE CONTROL

5DIMENSIONS − INDOOR0.63(16)Drain pipe7.68(195)Hanging armUnit: in (mm)27.56(700)23.62(600)8.27(210)Fig. 2 – Indoor UnitUNIT SIZE 9 12Depth in (mm) 8.

Seite 9 - Unit Outlet

6CLEARANCES − INDOORFig. 3 – Indoor Unit ClearanceSPECIFICATIONSHeat PumpSystemSize 9 12Indoor Model 40MBFQ09---3 40MBFQ12---3ElectricalVoltage, Phase

Seite 10 - FAN AND MOTOR SPECIFICATIONS

7APPLICATION DATAUNIT SELECTIONSelect equipment to either match or is slightly less than theanticipated peak load. This provides better humidity contr

Seite 11 - MAIN CONTROL BOARD

8WIRINGAll wires must be sized per NEC (National Electrical Code) orCEC (Canadian Electrical Code) and local codes. Use the ElectricalData table MCA (

Seite 12 - GUIDE SPECIFICATIONS

9AIR FLOW DATASYSTEM SIZE 9 12Indoor (CFM)High 280 280Medium 250 250Low 220 220SOUND PRESSURESYSTEM SIZE 9 12Cooling operation Indoor SoundPressuredBa