Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without incurring obligations.
REPLACEMENT COMPONENTS DIVISION LITERATURE NUMBER P274-4SO
© CARRIER CORPORATION 1106 6-01 REPLACES: New
PRINTED IN U.S.A. CATALOG NUMBER 570-203
Part Numbers P274-1100, 1200, 1300
.
GENERAL
The Totaline® 7-day programmable thermostats are wall-
mounted, low-voltage thermostats which maintain room tem
-
perature by controlling the operation of an HVAC (heating,
ventilation and air conditioning) system. Separate heating and
cooling settings and auto-changeover capability allow setback
of programming schedules for energy savings.
All thermostats allow up to 4 time/temperature settings to
be programmed per 24-hour period. Each thermostat stores
programs for 7 independent days. Batteries are not required.
During power interruption the internal memory stores pro
-
grams for an unlimited time and the clock continues to run for
at least 72 hours.
The Energy Star logo indicates this thermostat is designed
to significantly improve heating and cooling comfort levels
while reducing the cost to heat and cool indoor air space.
THERMOSTAT OPERATION
Thermostat Display — The thermostat display is locat-
ed in the top center of the thermostat. See Fig. 1. The following
information can be displayed on the screen:
mode (OFF, HEAT, COOL, AUTO, or EHEAT [P274-
1200,1300 models only])
fan setting (ON or AUTO)
hold status
auxiliary heat status (AUX HT [P274-1200,1300 models
only])
room temperature
desired temperature
clean filter status
time of day
day of the week
Programming the Thermostat — The thermostat has
programming buttons which allow time and temperature to be
entered into the thermostat. The programming buttons are be
-
hind the thermostat cover. To access the programming buttons,
pull on the hinged thermostat cover. See Fig. 1. The program
-
ming buttons are: Copy Previous Day, Program, Mode, Change
Day, End Program, Fan, Set Time, Reset Filter, and Hold.
The Up and Down buttons are used to change the current,
desired temperature set point and to scroll through program
-
ming settings. The Up and Down buttons are accessible from
the outside of the thermostat.
The daily schedule can be overridden in 2 ways: pressing
the Hold button or pressing the Up and Down buttons to
change the temperature set point.
HOLD BUTTON — Pressing the Hold button disables the
time and temperature schedule and holds the current desired
temperature set point. When a Hold is active, the HOLD
annunciator is displayed on the thermostat screen. The Hold
will remain active indefinitely. While HOLD mode is active
the set points can be adjusted and will remain at last changed
set point in HOLD mode for as long as HOLD mode remains
active. To release the Hold, press the Hold button a second
time.
FAN BUTTON The Fan button selects fan operation.
When the fan is set to ON, the fan will run continuously for
improved air circulation. When the fan is set to AUTO, the fan
will run during heating and cooling operation only.
MODE BUTTON — The Mode button selects the operating
mode of the thermostat. If OFF is selected, the thermostat will
not enter Heating or Cooling mode. If HEAT is selected, the
thermostat will only enter Heating mode (if the room tempera
-
ture is below the heating set point). If COOL is selected, the
thermostat will only enter Cooling mode (if the room tempera-
ture is above the cooling set point). If AUTO is selected, the
thermostat will enter Heating or Cooling mode based on the
room temperature and the heating and cooling settings. Heat
pump thermostats also have an EHEAT selection. If EHEAT is
configured by installer, the unit will use the second stage of
heating to provide heating if necessary. The annunciator for
each selection will be displayed on the thermostat when
selected.
AUTO-CHANGEOVER — When the thermostat mode is set
to AUTO, the thermostat will provide automatic changeover
from Heating to Cooling mode and Cooling to Heating mode
when required. The thermostat will automatically switch to
maintain the desired temperature setting. The thermostat does
not need to be manually changed from heating to cooling or
cooling to heating operation.
NOTE: It is recommended that auto-changeover mode not be
used if the outdoor temperature is consistently lower than 50 F
or greater than 80 F. In these cases, select Heating or Cooling
mode only.
SMART RECOVERY (HEATING MODE) — The smart
recovery function is designed to save energy by gradually
adjusting temperatures to meet scheduled set points. The Smart
Recovery function begins 1 to 1.5 hours before a scheduled set
point increase and gradually adjusts room temperature so the
temperature is at the new set point when the time period
begins. This is more efficient than making the system run at
full capacity until the desired temperature is met.
NOTE: Smart recovery does not apply to cooling operation.
IMPORTANT: Read entire instructions before program-
ming the thermostat.
OWNERS
MANUAL
Residential
Programmable
Thermostat
As an ENERGY STAR® Partner, Carrier Corporation
has determined that this product meets the
ENERGY STAR guidelines for energy efficiency.
TOTA-
LINE 1c.eps
gold-
1.pdf
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Thermostat

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.REPL

Seite 2

2Set Current Day — The Change Day button will change the day shown on the thermostat display to the next day. If a schedule has been entered, the ther

Seite 3

3Table 1 — Daily Comfort ScheduleNOTE: The cooling temperature set point must be at least 2 degrees higher than the heating temperature set point.Over

Seite 4 - LIMITED FIVE-YEAR WARRANTY

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.REPL