HEATING & COOLING
38QN
Heat Pumps—Outdoor Section
Installation and Start-Up Instructions
SAFETY CONSIDERATIONS
Installing and servicing air conditioning equipment can be
hazardous due to system pressure and electrical compo
nents. Only trained and qualified service personnel should
install or service air conditioning equipment.
Untrained personnel can perform basic maintenance, such
as cleaning and replacing filters. All other operations should
be performed by trained service personnel. When working
on air conditioning equipment, observe precautions in litera
ture and on tags emd labels attached to unit.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations. Have
fire extinguisher available. Read these instructions thor
oughly. Consult local building codes and National Electrical
Code (NEC) for special installation requirements.
A WARNING
Before installing or servicing unit, always turn off main
power to system. There may be more than one discon
nect switch. Turn off accessory heater power if applica
ble. Electrical shock can cause personal injury.
INSTALLATION
Step 1—Check Equipment and Jobsite—Install on a sohd,
level mounting pad. It is recommended that unit be
attached to pad using tiedown bolts. Fasten unit to pad
using holes provided in unit mounting feet. See Fig. 1.
AIRFLOW
A86167
A87150
Dimensions (ft-in.)
r-6" AIRFLOW AND
SERVICE CLEARANCE
AROUND UNIT — 12"
ON VALVE SIDE
Model 38QN 015-030 036-048 060
Diameters
1-9’2
2-5\ 3-3
Squares (minimum)
1-11
2-6 3-4
Tiedown Bolt
Locations C
0-6=4
0-9’'2
1-T=16
D
1-4
1-10^2
2-7
E 0-9V
1-1
1-5^8
Fig. 1—Dimensions, Connections and Mounting Pad (Refer to Tabie 1)
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obiigations.
Book| 1 I 4
PC 101 Cataiog No. 533-820 Printed in U.S.A. Form 38QN-10Si 10-87 Pg 1 Repiaces: 38QN-9Si
Tab l5al5a
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Heat Pumps—Outdoor Section

HEATING & COOLING38QNHeat Pumps—Outdoor SectionInstallation and Start-Up InstructionsSAFETY CONSIDERATIONSInstalling and servicing air conditi

Seite 2 - A CAUTION

Table 1—Physical DataMODEL 38QN015 018024030 036 042048 060OPER WT (lb)* 132151 155 180 195189 235 270REFRIGERANTControl22AccuRater'^'^ (Byp

Seite 3 - Compatible Fitting Repair

Sweat Connection—Use refrigerant grade tubing.1. Remove locking nut, plug, rubber 0-ring and Schrader core and cap from valve service port.2. Cut tu

Seite 4

CONNECT GROUND LEAD AND POWER WIRING- Connect ground lead to ground connection in control box for safety. Then connect power wiring. See Fi

Seite 5

THERMOSTAT SUBBASE HH93AZIT3 OR HH93AZI7540AQ OR 40QB FAN COIL COOLING CONTROL KIT TERMINAL BOARD38QNTERMINALBOARD(38QN/40AQ 0R40QB WITHOUT ELECTRIC H

Seite 6 - HEATING CYCLE CHECK CHARTS

HEATING CYCLE CHECK CHARTSPSIG(kPa)10(69)20(138)30(207)40(276)50(345)60(414)SUCTION PRESSURE AT SERVICE PORTSUCTION PRESSURE AT SERVICE PORTFig. 7—38Q

Seite 7

HEATING CYCLE CHECK CHARTS (cont)PRESS. AT SUCT. SERVICE PORT psigFig. 11—38QN036 Heating Cycie Check ChartSUCTION PRESSURE AT SERVICE PORTA87160Fig.

Seite 8

To check system operation during heating cycle, use correct Heating Cycle Check Chart (Fig. 7 through 14). These charts indicate whether a