This manual should remain with the unit.
2.4L
35kW Models
EPA Certified
Owner's Manual
Stationary Emergency Generator
Cover202 Rev. B 03/11 Part No. 0J2966
NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT
APPLICATIONS.

ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS
SHOULD ATTEMPT INSTALLATION!

DEADLY EXHAUST FUMES! OUTDOOR INSTALLATION
ONLY!
Seitenansicht 0
1 2 3 4 5 6 ... 79 80

Inhaltsverzeichnis

Seite 1 - Owner's Manual

This manual should remain with the unit.2.4L35kW ModelsEPA CertifiedOwner's ManualStationary Emergency GeneratorCover202 Rev. B 03/11 Part No.

Seite 2 - Table of Contents

SPECIFICATIONSSTATIONARY EMERGENCY GENERATORType...SynchronousRotor Insulation ...

Seite 3 - INTRODUCTION

WEATHER AND MAINTENANCE KITSTo keep the generator running at its peak, the following kits are offered:• Cold Weather Kit~ Recommended for climates wi

Seite 4 - SAFETY RULES

ALTERNATOR AC LEAD CONNECTIONSThe electrical wires in the unit’s AC connection (lower) panel should be installed according to the number of leads and

Seite 5 - Safety Instructions

Figure 7.4 — Stator Power WindingConnections - 3-phase, 120/208V (6 Lead)E3E200 (NEUTRAL)INTERNAL CONNECTIONSE1L-LL-NS1S1S4S4S6S6S3S3S5S5S2S2Figure 7.

Seite 6 - IDENTIFICATION RECORD

CONTROL PANEL INTERFACEUSING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such

Seite 7 - COOLANT RECOMMENDATIONS

8-2CntrlNexus001 Rev. D 04/11Control PanelACTIVATION CHARTCHOOSE LANGUAGE TROUBLESHOOTINGDisplay Reads: Use ARROW keys to scroll to desired lan-gua

Seite 8 - ENGINE PROTECTIVE DEVICES

INSTALLATION ASSISTANTInterconnect System Self Test Feature (follow the on-screen prompts).Upon power up, this controller will go through a system sel

Seite 9 - FUEL SYSTEM

SEQUENCE OF AUTOMATIC OPERATIONInitial Conditions: Generator in Auto ready to run, load being sup-plied by the Utility Source through the transfer sw

Seite 10 - SPECIFICATIONS

CHECK ENGINE MESSAGEThe control system has detected an emissions related fault. This fault cannot be cleared using the control panel interface. The u

Seite 11 - RECONFIGURING THE FUEL

OVERVOLTAGE ALARMIf the generator voltage rises above 110% for >3 seconds, an alarm will be issued.If the generator voltage rises above 130% for &g

Seite 12 - ALTERNATOR POWER WINDING

SECTION PAGEINTRODUCTION ... 1-1 Read this Manual Thoroughly ...

Seite 13 - General Information

MAINTENANCE ALERT CHARTCONDITION 1.6 CHERY 2.4/1800 MITSU 2.4/3600 MITSU 4.2 FORDChange oil & filter alert 3mo/30hrs break-in 1yr/100hrs3mo/30hrs

Seite 14 - ACTIVATE THE GENERATOR

8-8CntrlNexus001 Rev. D 04/11Control PanelACTIVATIONRUN LOGALARM LOGHISTORY STATUSCOMMANDSTATE VERSIONSDISPLAYGENERATORFREQUENCYENGINEHOURSENGINERPM

Seite 15 - Control Panel

STATIONARY EMERGENCY GENERATOR CONTROL AND OPERATIONRefer to the appropriate control panel operator’s manual for this unit.OPERATING UNIT WITH MANUAL

Seite 16 - OPERATION

GENERAL MAINTENANCE Before working on the Stationary Emergency Generator, ensure the following:The AUTO/OFF/MANUAL switch is in the OFF position.• Th

Seite 17 - ALARM AND WARNING MESSAGES

ENGINE COOLANTCheck coolant level in coolant recovery bottle. See the Specifications and Service Schedule sections.Add recommended coolant mixture as

Seite 18

Figure 10.3 – Engine Air FilterAir FilterSPARK PLUGSReset the spark plug gap or replace the spark plugs as neces-sary.1. Clean the area around the ba

Seite 19 - MAINTENANCE ALERTS

SERVICE SCHEDULESystem / ComponentFrequency ProcedureWeekly - WMonthly - MYearly - YInspect Change CleanFuelFuel Lines & Connections M XLubricatio

Seite 20

TroubleshootingTROUBLESHOOTING GUIDEPROBLEM CAUSE CORRECTIONEngine won’t crank. 1. Control panel 7.5 amp fuse blown. 1. Replace fuse.* 2. Loo

Seite 21 - MENU SYSTEM

13-1EmsnWrnty001 Rev. C 05/10United States Environmental Protection Agency Warranty StatementWarranty Rights, Obligations and CoverageThe United Sta

Seite 22 - Operation

13-2EmsnWrnty001 Rev. C 05/10United States Environmental Protection Agency Compliance RequirementsPurchaser’s/Owner’s Recordkeeping Responsibilities

Seite 23 - Oil Filter

INTRODUCTIONThank you for purchasing this model of the stationary emergency generator product line.Every effort was expended to make sure that the inf

Seite 25 - Air Filter

1 0F9677 1 ROTOR-2390-45KD1 CPL 0G0056 1 ROTOR-2390-35KD1 CPL 0G0959 1 ROTOR-2390-45KD1 CPL (G2) 0G1155 1 ROTOR-2390-35KD1 CPL (G2) 0

Seite 29

EXPLODED VIEW: CONBOX C2 CPL DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-8608-E Page 4 of 8 DATE: 5/12/11 ITEM PART# QTY. DESCRI

Seite 30

EXPLODED VIEW: CONBOX C2 CPL DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-8608-E Page 5 of 8 DATE: 5/12/11 ITEM PART# QTY. DESCR

Seite 31

EXPLODED VIEW: CONBOX C2 CPL DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-8608-E Page 6 of 8 DATE: 5/12/11 ITEM PART# QTY. DESC

Seite 32

EXPLODED VIEW: CONBOX C2 CPL DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-8608-E Page 7 of 8 DATE: 5/12/11 ITEM PART# QTY. DESCR

Seite 33

EXPLODED VIEW: CONBOX C2 CPL DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-8608-E Page 8 of 8 DATE: 5/12/11 THIS PAGE LEFT INTENTI

Seite 34

SAFETY RULESStudy these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and

Seite 36

1 0F9517 1 WELDMENT FRAME 2.4L C2 2 052860 4 NUT FLANGED HEX M12-1.75 3 052251 4 DAMPENER VIBRATION 40 BLUE 4 052257 4 SPACER .49 X .62 X

Seite 38

1 0F3408B 1 BATTERY TRAY C1 CPL2 0F3411 1 STRAP BATTERY RETAINMENT3 025507 REF WASHER SHAKEPROOF EXT 7/16 STL4 052212 REF SCREW HHC M10-1.25 X 25 G8.8

Seite 40

EXPLODED VIEW: AIR CLEANER 2.4L G2 TURBO DRAWING #: 0H1955 GROUP D APPLICABLE TO: REVISION: H-4431-C PAGE 2 OF 2 DATE: 5/6/09 ITEM PART# QTY.

Seite 43

1 0H30830ST03 1 WELDMENT RADIATOR SUPPORT C2 2 0F2608 1 RADIATOR 598 X 568 X 49 CPL RH 3 0E3256 1 V-BELT A58 (60IN O.C.) DDC S60 4 046526

Seite 45 - GROUP D

If personnel must stand on metal or concrete while installing, • operating, servicing, adjusting or repairing this equipment, place insulative mats ov

Seite 48

EXPLODED VIEW: ENGINE COMMON PRT 2.4L G2 TURBO 36K DRAWING #: 0H7321 GROUP D APPLICABLE TO: REVISION: H-7244-D Page 3 of 4 DATE: 8/10/10

Seite 49

EXPLODED VIEW: ENGINE COMMON PRT 2.4L G2 TURBO 36K DRAWING #: 0H7321 GROUP D APPLICABLE TO: REVISION: H-7244-D Page 4 of 4 DATE: 8/10/10

Seite 51

ITEM PART# QTY. DESCRIPTION 1 0G9936 1 TURBOCHARGER 2.4L 36KW 1800RPM 2 0H0788 1 GASKET EXH MAN/TURBO 3 064096B 1 OIL SUPPLY 3LHA(38

Seite 53

EXPLODED VIEW: FUEL SYSTEM 2.4L 36KW TURBO DRAWING #: 0H7579 GROUP E APPLICABLE TO: REVISION: -A- PAGE 2 OF 2 DATE: 3/22/10 ITEM PART# QTY.

Seite 55

ITEM PART# QTY. DESCRIPTION 1 0G86870ST03 1 BRACKET MUFFLER 2 0G8686 1 BRACKET STIFFENER 3 0G3919 1 UPPER EXHAUST PIPE ASM 4 0G61

Seite 56

IDENTIFICATION RECORDDATA LABELEvery generator set has a DATA LABEL that contains important information pertinent to the generator. The data label, wh

Seite 58

EXPLODED VIEW: EV ENCLOSURE C2 DRAWING #: 0J2818 GROUP F APPLICABLE TO: REVISION: -A- Page 2 of 2 DATE: 11/3/10 ITEM PART# QTY. DESCRIPTI

Seite 67

EQUIPMENT DESCRIPTIONThis equipment is a revolving field, alternating current Stationary Emergency Generator. It is powered by a gaseous fueled engine

Seite 77

GENERAC POWER SYSTEMS “FIVE YEAR” LIMITED WARRANTY FOR HONEYWELLSINGLE-PHASE LIQUID-COOLED EMERGENCY GENERATORS BELOW 50KWFor a period of five (5) yea

Seite 78

ENGINE PROTECTIVE DEVICESThe Stationary Emergency Generator may be required to operate for long periods of time without an operator on hand to monitor

Seite 79

BackPg001 Rev. A 04/07

Seite 80 - BackPg001 Rev. A 04/07

FUEL SYSTEMFUEL REQUIREMENTSThe Stationary Emergency Generator may be equipped with one of the following fuel systems:• Natural gas fuel system• Pro