90MA/MU Single-Package Marine Cooling Units Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
TABLE 3 - RECOMMENDED LINE SIZES (INCHES) REMOTE CONDENSERS DISCH LIQUID DISCH LIQUID DISCH LIQUID DISCH LIQUID404 R-407C 1/2 3/8 5/8 3/8 5/8 3/8 5/
Step 12 - Make Electrical Connections GENERAL - Provide an adequate fused disconnect switch within sight of the unit. Provision for locking switch o
SERVICE WARNING NEVER reach into unit while fan is running. LOCK OPEN AND TAG unit disconnect before working on fan. Remove fuses and take them w
Evaporator Coil - Observe fan compartment Caution note at the beginning of the Service section. Remove dirt and debris from evaporator coil as requ
Charging the System (90MA) - These units are shipped with a full operating charge. If recharging is necessary (complete charge lost), weigh in amount
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
FOR NOTES AND LEGEND, SEE FIGURE 13 FIGURE 12 WIRING SCHEMATIC - 90MA/MU*04/*06 Manufacturer reserves the right to discontinue, or change at
FIGURE 13 COMPONENT ARRANGEMENT - 90MA/MU*04/*06 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
FOR NOTES AND LEGEND, SEE FIGURE 15 FIGURE 14 - ELECTRICAL SCHEMATIC - 90MA/MU*08/*12 Manufacturer reserves the right to discontinue, or chan
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
FIGURE 15 - COMPONENT ARRANGEMENT - 90MA/MU008/012 Manufacturer reserves the right to discontinue, or change at any time, specifications or desig
FIGURE 16 – MOUNTING BASE ASSEMBLY – 90MA/MU*04/*06 Manufacturer reserves the right to discontinue, or change at any time, specifications or de
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Pr
FIGURE 1 - BASE UNIT INTERIOR DETAILS (TYPICAL UNIT SHOWN) Step 4 - Rig and Place Unit - NOTE: Install accessories before placing unit. a. Prov
DIMENSION “D” MUST BE EQUAL ALL AROUND FIGURE 3 - HORIZONTAL WHEEL CENTERING FIGURE 4 - CONCENTRIC WHEEL ALIGNMENT Step 6 – Check Fan Shaft and